SENSEEN=DISABLED, VREGDIS=INACTIVE, VBUSIVLDIEN=DISABLED, VBUSIVLDI=NOT_SET, BGDIS=INACTIVE, SUSEN=DISABLED, VBUSVLDF=NOT_SET
Module Control
VBUSVLDF | VBUS Valid Flag. 0 (NOT_SET): The current voltage on the VBUS pin is below the valid threshold. 1 (SET): The current voltage on the VBUS pin is above the valid threshold. |
SUSEN | Voltage Regulator Suspend Enable. 0 (DISABLED): Disable regulator suspend mode. 1 (ENABLED): Enable regulator suspend mode. |
BGDIS | Band Gap Disable. 0 (INACTIVE): Enable the voltage regulator band gap. 1 (ACTIVE): Disable the voltage regulator band gap. |
SENSEEN | VREGIN Sense Enable. 0 (DISABLED): Disable VREGIN voltage sensing. 1 (ENABLED): Enable VREGIN voltage sensing. |
VBUSIVLDI | VBUS Invalid Interrupt Flag. 0 (NOT_SET): The voltage on the VBUS pin has not dropped below the valid threshold. 1 (SET): The voltage on the VBUS pin dropped below the valid threshold since the last time this bit was cleared. |
VBUSIVLDIEN | VBUS Invalid Interrupt Enable. 0 (DISABLED): Disable the VBUS invalid interrupt. 1 (ENABLED): Enable the VBUS invalid interrupt. |
VREGDIS | Voltage Regulator Disable. 0 (INACTIVE): Enable the voltage regulator. 1 (ACTIVE): Disable the voltage regulator. |